Study of the Nonenzymatic CZO Lactic Acid Sensor Modified by Graphitic Carbon Nitride and Iron–Platinum Nanoparticles
Yu-Hsun Nien,Zhi-Xuan Kang,Jung-Chuan Chou,Chih-Sung Ho,Chih-Hsien Lai,Po-Yu Kuo,Yung-Yu Chen,Yu-Hao Huang
DOI: https://doi.org/10.1109/ted.2021.3104271
IF: 3.1
2021-10-01
IEEE Transactions on Electron Devices
Abstract:This study proposed a nonenzymatic sensor for lactic acid detection based on copper doped zinc oxide (CZO) modified by graphitic carbon nitride (g-C<sub>3</sub>N<sub>4</sub>) and iron–platinum nanoparticles (FePt NPs). The silver paste electrodes of the sensor were prepared using screen printing technology, and the CZO sensing film was deposited using radio frequency (R.F.) sputtering system. The g-C<sub>3</sub>N<sub>4</sub> nanosheet solution was prepared through liquid exfoliating of the g-C<sub>3</sub>N<sub>4</sub> in water. The sensing film was modified by adding different contents of the FePt NPs in g-C<sub>3</sub>N<sub>4</sub> solution. The various concentrations of the FePt NPs were 0.03, 0.1, and 0.3 wt%. The <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.787ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 769.5 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-56" x="0" y="0"></use></g></svg></span> – <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.636ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 704.5 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-54" x="0" y="0"></use></g></svg></span> measurement system was applied to investigate the sensing characteristics of the lactic acid sensors based on CZO sensing film modified by g-C<sub>3</sub>N<sub>4</sub> and FePt NPs. The surface morphology of the sensor was analyzed by scanning electron microscope (SEM), X-ray diffraction (XRD), and dynamic light scattering (DLS). In this work, the 0.1 wt% FePt NPs-g-C<sub>3</sub>N<sub>4</sub> lactic acid sensor has the best sensitivity, linearity, response time, and the limit of detection (LOD).<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMATHI-56" d="M52 648Q52 670 65 683H76Q118 680 181 680Q299 680 320 683H330Q336 677 336 674T334 656Q329 641 325 637H304Q282 635 274 635Q245 630 242 620Q242 618 271 369T301 118L374 235Q447 352 520 471T595 594Q599 601 599 609Q599 633 555 637Q537 637 537 648Q537 649 539 661Q542 675 545 679T558 683Q560 683 570 683T604 682T668 681Q737 681 755 683H762Q769 676 769 672Q769 655 760 640Q757 637 743 637Q730 636 719 635T698 630T682 623T670 615T660 608T652 599T645 592L452 282Q272 -9 266 -16Q263 -18 259 -21L241 -22H234Q216 -22 216 -15Q213 -9 177 305Q139 623 138 626Q133 637 76 637H59Q52 642 52 648Z"></path><path stroke-width="1" id="MJMATHI-54" d="M40 437Q21 437 21 445Q21 450 37 501T71 602L88 651Q93 669 101 677H569H659Q691 677 697 676T704 667Q704 661 687 553T668 444Q668 437 649 437Q640 437 637 437T631 442L629 445Q629 451 635 490T641 551Q641 586 628 604T573 629Q568 630 515 631Q469 631 457 630T439 622Q438 621 368 343T298 60Q298 48 386 46Q418 46 427 45T436 36Q436 31 433 22Q429 4 424 1L422 0Q419 0 415 0Q410 0 363 1T228 2Q99 2 64 0H49Q43 6 43 9T45 27Q49 40 55 46H83H94Q174 46 189 55Q190 56 191 56Q196 59 201 76T241 233Q258 301 269 344Q339 619 339 625Q339 630 310 630H279Q212 630 191 624Q146 614 121 583T67 467Q60 445 57 441T43 437H40Z"></path></defs></svg>
engineering, electrical & electronic,physics, applied