Effect of pollutant loading rate on campus wastewater treatment performance with a subsurface infiltration system: A field study

Yinghua Li,Haibo Li,Xin Wang,Hong Wang
2012-01-01
Fresenius environmental bulletin
Abstract:To characterize the effect of pollutant loading rate (PLR) on the treatment performance of a subsurface wastewater infiltration (SWI) system, a field study was carried out with the PLR 6.71, 9.30, 16.80 and 20.00 g BOD/ m(2).d, respectively. The results showed that PLR had negative effect on the pollutant removal efficiencies. Balancing between the superior effluent quality and less land area usage, the optimal PLR was 16.80 g BOD/ m(2).d. Under this condition, the removal efficiencies was 87.5 +/- 1.6% for COD, 91.8 +/- 2.7% for TP, 86.9 +/- 2.0% for NH3-N and 60.1 +/- 1.1% for TN. The analysis of NH3-N, NO2-N and NO3-N concentrations of the raw sewage and effluents, as well as the concentration variations of NH3-N, NO3-N and NO2-N with depth suggested that adsorb-nitrification-denitrification was the main path for the nitrogen removal. The higher urease activity was achieved nearer the inlet area. The urease activity was in positive correlation with temperature, with correlation equation U = 0.3668T + 8.5679 and coefficient 0.957. Nitrate reductase activity was arranged in the following descending order when soil depth was concerned, 0.3, 0.5, 0.7, 0.9 and 1.1 m. With respect to nitrite reductase activity, the descending order was 0.5, 0.3, 0.7, 0.9 and 1.1 m.