Nitrogen and Phosphorus Removal Mechanism in Subsurface Wastewater Infiltration System

张建,黄霞,魏杰,胡洪营,施汉昌
DOI: https://doi.org/10.3321/j.issn:1000-6923.2002.05.014
2002-01-01
Abstract:Nitrogen and phosphorus removal mechanism in subsurface wastewater infiltration system treating domestic wastewater was studied. The hydraulic loading was 2 cm/d. The experimental results showed that the removal rates of NH4+-N, COD and total phosphorus were all over 90%. The effluent concentrations of NH4+-N, COD and totalphosphorus below 0.2, 30 and 0.025 mg/L respectively. The total nitrogen removal rate was achieved as 63.5%. The removal efficiency of contaminants could be improved through strengthening equalization of flow distribution. Biological nitrogen removal through nitrification and denitrification was the main removal mechanism of nitrogen, which could remove about 50% of influent total nitrogen. How to improve denitrification process was the key to enhance nitrogen removal rate. Phosphorus in sewage was mainly removed by fixation processed in the soil, such as adsorption andchemical precipitation.
What problem does this paper attempt to address?