Effect of Constructed Wetland on Treatment of Municipal Sewage at Lower Loading Rates

FENG Ming-lei,ZHANG Zhi-yong,YANG Lin-zhang,KONG Li-xi
DOI: https://doi.org/10.3969/j.issn.1671-4652.2007.03.017
2007-01-01
Abstract:Performance and dynamic removal of typical pollutants in municipal sewage treated by 3 simulating constructed wetland cells at lower loading rates were observed,and the impact of pollutant loading rate for pollutants' removal was also investigated.The results indicated that the constructed wetland planted with ryegrass(Lolium multiflorum L.) had good performances for treatment of municipal sewage.The removal efficiencies of CODCr,TN(total nitrogen),TP(total phosphorus),NH+4-N and NO-x-N were 75.6%,93.2%,95.7%,96.2% and 66.5%,respectively.Most of CODCr(65.7%),TN(87.2%) and TP(95.0%) were degraded within one day after sewage affused,and adsorption and immobility of stuffing may be an important precondition for pollutants' rapid removal.Whereas the removal of NO-x-N accumulated by microbial nitrification needed longer than 5 days resident time.The removal loading rates of CODCr,TN,TP and NH+4-N were positively correlated with their pollutant loading rates.The pollutant loading rates had great influence on the removal of typical pollutants in municipal sewage.
What problem does this paper attempt to address?