Performance of Pollutants Removal and Flow Pattern of Constructed Wetland System

刘超翔,胡洪营,孟远航,黄霞,施汉昌,钱易
DOI: https://doi.org/10.3321/j.issn:1000-4602.2003.z1.004
2003-01-01
Abstract:Subsurface flow type constructed wetland system used for domestic sewage treatment has average removal rate of COD and TP above 85% and 80% respectively,and removal rate of total nitrogen about 55%.The sample analysis result indicated that in the first 1/3 part of the system,it is more efficient in removal of pollutant.Lithium chloride,a conservative tracer,was used to analyze the flow pattern in the wetland,and it was found that the residence time distribution curve lies between ideal plug-flow and completely mixed model,with the characteristics of early appearance of peak,showing some short circuiting current or dead zone existing in the wetland.
What problem does this paper attempt to address?