Thermal simulation of micro-channel flat tube condenser for refrigerator

LIU Gang-Yun,HUANG Chang-Hua,LIU Ying-Wen
2012-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:A new idea that micro-channel flat tube condenser could be used to household refrigeration system has been provided. In order to validate it feasible, the physical models and programs of hot-wall condenser and micro channel flat tube condenser have been built and developed respectively in this paper, based on finite difference method (FDM) and equivalent thermal resistance method. The thermal performance of two kinds of condensers has been analyzed and compared with each other in detail. The result has shown that new flat tube condenser could increase the heat rejection which was more than that of hot-wall condenser about 25 percent, and it could further improve the refrigerator's EER. Otherwise, the influence of pore number, pore diameter, flat tube width, plate thickness and refrigerant flow rate on the heat rejection performance of flat tube condenser has been studied in detail. It was found that refrigerant flow and flat tube width have been the important factors which influence the heat rejection performance of flat tube condenser. This paper could provide the theoretical base on optimal design of flat-tube condenser.