Fire protective coating of concrete-filled square hollow sections being exposure to two-opposite-side fire

Lv Xue-Tao,Yang Hua,Zhang Su-Mei
2012-01-01
Abstract:CFST columns may be exposed to two-opposite-side fires. The decrease of fire exposure boundaries leads to generally lower cross-sectional temperature, which causes different fire resistance behaviors from four-side fire condition. A series of parametric analysis was carried out for the fire resistance of the columns with fire-proof coating in two-opposite-side fire, hereafter a set of design tables in which minimum thickness of fire-proof coating may be determined, and the tables may provide references for fire design of those concrete-filled SHS being exposed to two-opposite-side fire in construction application.