Fire Performance and Design Method of Concrete- Filled Steel Rectangular Hollow Section Columns

杨有福,韩林海
DOI: https://doi.org/10.3321/j.issn:1000-6869.2004.01.004
2004-01-01
Abstract:Eight concrete filled steel rectangular hollow section columns with or without fire protection subjected to axial or eccentric loads under standard fire curve (ISO—834 and GB/T9978—1999) had been experimentally investigated and the results were presented in this paper. The experimental results showed that the sectional dimension and the fire protection thickness had a significant influence on the fire resistance time of rectangular composite columns, however, the load eccentricity ratio had moderate influence on the fire resistance time, and the fire protection thickness determination methods for pure steel structure columns in GB50045—95 were unsuitable for the composite columns. Based on the parametric analysis, the simplified formulas for the calculation of the fire resistance time and the fire protection thickness of the composite columns are put forward, the calculating results are in good agreement with the numerical and experimental results, and tend to safety in general. The achievements in this paper may be referenced for the fire protection design of practical engineering with concrete filled steel rectangular hollow section columns.
What problem does this paper attempt to address?