Abstract:Finite element method is applied for the calculations of temperature fields of concrete filled steel tubes under fire. A theoretical model that calculates deformations and strength of beam-column in fire and fire resistance is described in this paper. A comparison of results calculated using this model with the results of tests, there is good agreement. Based on the theoretical model, influence of the changing strength of the materials, sectional dimensions, steel ratio, load eccentricity and slenderness ratio on the fire resistance is discussed. The theoretical model in this paper were used to provide data on the necessary fire protection measures for the concrete filled steel tubular columns used in a high-rise building, SEG Plaza in Shen-Zheng City, South of China.