Abstract:To know about fireproof performances of concrete filled tubes(CFT) of fire‐resistant(FR) steel with circular cross‐section ,the temperature field of CFT of ordinary steel under the fire heating curves was simulated using ANSYS .The fire resistance and load‐bearing capacity of CFT of FR steel were solved with numerical technique under different diameters , slenderness ratio , steel ratio , steel strength , concrete strength ,exposure time ,load eccentricity ratio and load ratio . The simplified calculation formula for predicting the fire resistance time and bearing capacity was deduced , which is found to be in good agreement with numerical results .The calculation formula may be referenced for the fire protection design of practical engineering .Parametric analyses show that the fire resistance time and bearing capacity of CFT of FR steel increase significantly in a certain period of exposure time compared with CFT of ordinary steel . Therefore ,the thickness of fire‐proof coating can be decreased or abolished .