FIRE RESISTANCE OF CONCRETE-FILLED CIRCULAR STEEL TUBULAR COLUMNS WITH INTERNAL PROFILED STEEL UNDER AXIAL COMPRESSIVE

Wenjing Mao,Yanli Shi,Wenda Wang
2016-01-01
Abstract:A finite element (FE) model of CFST columns with internal profiled steel was established using ABAQUS software in this paper, which was verified by the experimental results reported in the literature. The fire performance of CFST columns and CFST columns with internal profiled steel were studied respectively in same section steel ratio condition, and the reasons for the fire resistance improved were analyzed by temperature filed distribution and stress distribution. A series of parametric studies were performed such as steel tube ratio, internal profiled steel ratio and steel grade, the influence rule on fire resistance of distribution of steel tube ratio, the quantitative analyses were calculated by defining bearing capacity improvement index IdexN(c) and the effect factor of fire resistance Idext. It can be found that fire endurance improved obviously when part of steel in CFST columns were put in core concrete as internal profiled steel keeping total steel ratio unchanged. The best steel tube ratio makes the bearing capacity at ambient temperature and fire resistance play optimal performance was 0.5-0.6.
What problem does this paper attempt to address?