Pitting corrosion characteristics of boiler water-wall tubes influenced by 20G and 15CrMo materials in Cl - solution

Zhiping Zhu,Shuhua Xiong,Yongfu Zhao,Xiaocui Guo,Yu Zhou
2012-01-01
Abstract:In order to investigate the influence of Cl - on the pitting corrosion of water-wall tube 20 G and 15CrMo materials at room temperature and high temperature, a series of experiments including electrochemical measurement and high-temperature weight loss were carried out. The tested specimen surface was characterized by transmission reflection metallurgical microscopy, scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), and X-ray diffraction (XRD). The experiment results show that Cl - accelerate pit corrosion of 20 G and 15CrMo specimens at room temperature, 15CrMo specimens have higher corrosion resistance than 20 G specimens, and Cl - also accelerate corrosion at high temperature. The corrosion mechanism of Cl - for water-wall tube is the competitive adsorption mechanism of Cl - and OH - at room-temperature, an intermediate complex (FeOHCl) is formed; Cl - acted as a catalyst at high-temperature, which induce the Fe 2+ hydrolysis, and form loose and unprotected Fe 3O 4 film. In the actual operation of power plant, Cl - concentrations must be controlled less than 0.2 mg/L in feed water. © 2012 Chin. Soc. for Elec. Eng.