Experimental Investigation of Corrosion Associated with Gaseous HCl in the Superheaters in a Biomass Boiler

Zhiyong Wu
2008-01-01
Abstract:Corrosion experiments with metals 20 G and 12Cr1MoVG were conducted by simulating the atmosphere of the superheaters in a biomass boiler to choose appropriate materials preventing high temperature corrosion. Corrosion dynamic curves were plotted using the mass gain. The metal elements were analyzed after the experiments using SEM (scanning electron microscope)-EDS (energy dispersive spectrometer) method and X-ray diffraction (XRD) to detect the appearance, the element contents and the compositions of the corrosion products. The results show that both the two metals have poor anti-corrosion abilities, with 20 G being a little better than 12Cr1MoVG below 500℃. The anti-corrosion abilities of the two metals, especially 20 G, decrease with increasing temperature.
What problem does this paper attempt to address?