Study on Radial Thermal-Hydraulic Characteristics of Once-Through Steam Generator of Sodium-Cooled Fast Reactor
Yapeng Liu,Bo Wang,Dalin Zhang,Zhenyu Feng,Xinyu Li,Wenxi Tian,Suizheng Qiu,Guanghui Su
DOI: https://doi.org/10.1115/icone31-135219
2024-01-01
Abstract:Abstract In sodium-cooled fast reactor, once-through steam generator (OTSG) is an important heat transfer component, and it is also one of components that is prone to failure. The safe and stable operation of this equipment is crucial to the safety of sodium-cooled fast reactors. The steam generator has a sizable number of heat exchange tubes. Variations of mass flow rates in distinct radial zones on the primary side of the steam generator are caused by structural variations in the steam generator, which in turn cause variations in flow and heat transfer along the radial direction. Further thermal stresses are produced as a result of these variations in the fluid and structure’s temperatures. As a result, more detailed modeling of the primary side of the steam generator is required. An essential technique for a detailed simulation of the primary side of the once-through steam generator is computational fluid dynamics (CFD). However, CFD method is time-consuming and difficult to apply to long-term transient analysis. Therefore, in order to calculate the long-term transient operating conditions, and considering the radial thermal-hydraulic difference on the primary side of the steam generator, a radial parallel multi-channel model is developed to analyze the radial thermal-hydraulic difference of the once-through steam generator. This model can use multiple parallel channels to model the primary and secondary sides of the heat exchange tubes in different areas of the steam generator. The lateral momentum exchange between the heat exchange tubes is not considered in the model, but the energy exchange between different radial regions can be considered in the form of heat conduction. First, the model was verified using the transient test conditions carried out on the once-through steam generator test facility (SGTF) in India. The calculation results were consistent with the test results, and the deviation was within 10 K. The test results and calculation results in different radial areas were compared, and the program’s ability to calculate radial thermal-hydraulic differences was verified. Finally, the test conditions of the steam generator prototype of the China Fast Reactor 600 (CFR600) were analyzed. By considering the difference in radial flow distribution, the results of single channel model and radial multi-channel model are compared, and the impact of the radial thermal-hydraulic difference of the once-through steam generator on the simulation results was analyzed. The calculation results show that the radial multichannel model can effectively analyze the flow/heat transfer differences of the steam generator in different radial areas. It is verified that the model can analyze the radial thermal-hydraulic difference of the steam generator, and can provide reference data for the rapid thermal-mechanical coupling analysis of the steam generator.