Time Domain Model for Once-Through Helical Coil Steam Generator for High-Temperature Gas-Cooled Reactors

Hanliang Bo
2012-01-01
Abstract:The once-through helical coil steam generator(SG) is one of the key parts of high-temperature gas-cooled reactor systems.A time domain model was developed for the steam generator to investigate the dynamic heat transfer and flow processes in both the helium and water/steam sides.A drift-flux model was used for the water/steam two-phase flow,while the helium flow was described by a one-dimensional compressible flow model.The heat transfer and flow resistance were computed by correlations.To improve convergence,a pressure-correction method capable of solving low-speed compressible flows was used for both the helium and water/steam flows.The predicted steady state temperature fields in the steam generator agree well with THTR-300 SG experiments.Typical two-phase flow oscillations can also be captured.
What problem does this paper attempt to address?