Experimental Response of Turbine Flowmeter in Horizontal Triphase Flow

Jin-hai HU,Xing-bin LIU,Guo-min XUE,Chun-hui HUANG,Ming-yuan JU
DOI: https://doi.org/10.3969/j.issn.1004-1338.2006.06.003
2006-01-01
Abstract:The response of turbine flowmeter to oil-water-gas triphase flow rate is experimented in horizontal well models.The experimental data are reduced to 3 types of response relationships: the relationships between the rotation speed of the turbine flowmeter(RTF) and the total biphase flow rate are linear,their slops(i.e.the K of the turbine) are almost not affected by the gas flow rate and the water cut,while a bigger gas flow rate results in a bigger interception;the relationships between the RTF and the gas flow rate are linear and almost not affected by the water cut and the total oil-water flow rate;the relationships between the RTF and the total oil-gas-water flow rate are linear too,but the K of the turbine will increase as the fluid density increases.It indicates that the density correction is necessary to obtain a correct total triphase flow rate.