Analysis of Experiments of Cross-correlation Flowmeter in Horizontal Multi-phase Loop

HU Jin-hai,LIU Xing-bin,HUANG Chun-hui,JU Ming-yuan,ZHANG Yu-hui,LI Ying-wei
DOI: https://doi.org/10.3969/j.issn.1004-1338.2006.01.015
2006-01-01
Abstract:The measuring principle and circuit structure of the Φ38 mm conductance cross-correlation flowmeter are simply introduced. The results of dynamic experiment of the flowmeter under different water-cut and different flowrate are also introduced.The experimental results show that there is a good linear relationship between the tool′s output response and the flowrate.When the watercut is(over) 60%,the output response increases as the watercut increases;but when the watercut is below 70%,the Φ38 mm conductance cross-correlation flowmeter has good repeatability,that is,the repeatability error is not over 2%.