Study on Pollutant Removal Efficiency of Combined System of High Concentration Powdered Activated Carbon and Ultrafiltration

YU Ming-mei,YU Shui-li,RUAN Ting,MA Cong
2011-01-01
Abstract:The single membrane technology is difficult to remove organic matter and ammonia nitrogen in raw water,and severe membrane fouling exists.The treatment efficiencies of the organic matter and ammonia nitrogen by combined system of high concentration powdered activated carbon and UF membrane were investigated.The results show that the combined system has higher removal efficiencies of UV254,UV350,TOC,turbidity and ammonia nitrogen.The total number of bacteria is zero in the effluent.During the whole experimental stage,the average removal rates of UV254 and UV350 are 95% and 96% respectively,the average removal rate of TOC is 72%,the average removal rate of turbidity is 98% or more,and the effluent turbidity is always less than 0.1 NTU.During the stable operation stage of the equipment,the average removal rate of ammonia nitrogen is 82%.During the whole experimental stage,transmembrane pressure is characterized by stepwise increase,from the initial 0.003 MPa to the final 0.030 MPa.The membrane fouling is effectively relieved.
What problem does this paper attempt to address?