Membrane Fouling Characteristic in Combined Process of Activated Carbon and Ultrafiltration

Tie-jun QIAO,Xiao-hui TANG,Xi-hui ZHANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2010.17.010
2010-01-01
Abstract:The fouling of ultrafiltration membrane in combined process of activated carbon and ultrafiltration was investigated in terms of physical cleaning,chemical cleaning and pollutants.The results show that the transmembrane pressure(TMP) is increased by 75% from 20 to 35 kPa,and the specific membrane permeate flux(SMPF) is decreased by 50% approximately from 3.8-4.6 L/(m2·h·kPa) to 1.8 L/(m2·h·kPa).The removal efficiency of irreversible membrane foulants by physical cleaning is poor.SMPF is decreased to about 70%,and TMP is increased by 100% with prolongation of operation time.The recovery rates of TMP and SMPF are 82% to 100% and 86% to 100% respectively after chemical cleaning.Membrane fouling is caused by organic compounds,microorganisms and metal ions,including high valent metal ions(Fe3+ and Al3+),divalent metal ions(Ca2+ and Mg2+) and organic compounds with small molecules(mainly alkyl-and aromatic-hydrocarbons).Organic compounds are deposited on membrane surface and block membrane pores.High valent metal ions are mostly adsorbed and deposited on membrane internal wall,while divalent metal ions are adsorbed and deposited on membrane internal wall and in pores.