Treatment of textile wastewater using ultratfiltration and reverse osmosis dual membrane system

Zeng Hangcheng,Zhang Guoliang,Meng Qin,Chen Jinyuan,Wang Qidong
2008-01-01
Abstract:Ultrafiltration and reverse osmosis combined membrane processes were applied for in the textile wastewater treatmeat and reuse.As pretreatment,ultrafiltration had good performance on removal of turbidity and organic matters with high molecular weight,which could guarantee good quality of feed water for reverse osmosis.Two kinds of reverse osmosis membranes(BW30,CPA2) were tested and compared later by carrying out the lab-test under different operating pressures,times and temperatures.It appeared that permeate had COD value lower than 10 mg/L and conductivity no more than 80 μS/cm.The rejection for COD and salt could reach as high as 99% and 93%,respectively.Permeate of both two membranes could be recycled to most of dyeing process.Compared with CPA2,BW30 had a little better quality of permeate,but its flux was somewhat lower.At last,permeate flux decrease due to membrane fouling was also analyzed.
What problem does this paper attempt to address?