Stopping Power of Au and Ag for He Ions

Xiaojing Huang,Xiting Lu,Changwen Jin,Chengfang Zhou,Yanlin Ye,Zonghuang Xia,Hongtao Liu,Dongxing Jiang
DOI: https://doi.org/10.1088/0256-307x/10/4/004
1993-01-01
Abstract:Energy loss of 0.45-5.0 MeV 4He ions in Au and Ag films were measured with the Rutherford backscattering method, and the stopping powers at lower energy range were extracted by comparing with that determined by Anderson et al. at higher energy range. Significant deviation between the experimental data and the semiempirical calculations by TRIM-90 appears around the stopping maximum. The accuracy of our results was expected to be ±1%.
What problem does this paper attempt to address?