Approximate Calculation of Electric-Vehicle Inverter Power-Loss in Two Control Strategies

Yuan ZHU,Gensheng LI,Zhihong WU,Guangyu TIAN
DOI: https://doi.org/10.3969/j.issn.1674-8484.2013.01.013
2013-01-01
Abstract:An approximation method for calculating inverter power loss was proposed to guide selecting power module and design heat sink with higher efficiency of permanent magnet synchronous motors for space vector pulse width modulations (SVPWM) which are widely used in the electric vehicle drive system. Power losses in different vector sectors were calculated using this method, and then compared according to the characteristics and parameters of insulated gate bipolar transistors (IGBTs) for two drive-system control-strategies of permanent magnet synchronous motors. For one control strategy, the d-axis armature current is zero (), and the other is with the maximum torque per Ampere (MTPA). The results show that the total power loss of the inverter under the MTPA control strategy is smaller than that for the other control strategy, thereby resulting in lower temperature rise of inverter heat sink.
What problem does this paper attempt to address?