Direct simulation of flashing liquid jets using the MPS method

Ri-Qiang Duan,Sheng-Yao Jiang,Seiichi Koshizuka,Yoshiaki Oka,Akira Yamaguchi
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2005.06.038
IF: 5.2
2006-01-01
International Journal of Heat and Mass Transfer
Abstract:Some leakage problems can result in the occurrence of spray flash evaporation in power plants. In order to investigate the thermal characteristics of spray flash evaporation under high temperature and high pressure, we carried out a series of experiments in a high pressure and high temperature steam-water test loop. Experimental results revealed that the flash evaporation finished within a short distance under high temperature and high pressure, indicating this was a quite violent process. The increase of the flow rate of the feed water led to the increase in the inflection point distance. The increase of the initial water temperature and injection pressure resulted in a slightly improved spray flash evaporation. The flow rate played a dominant role in the flash evaporation under high temperature and high pressure. The inflection point distance predicted by the correlation showed greater dependence on the Froude number.
What problem does this paper attempt to address?