Design and Operation Control of Surface Aeration A/A/O Oxidation Ditch in Wastewater Treatment Plant

Bo-lin LI,Zhi ZHANG,Li-ping REN,Jie-yun CHEN
DOI: https://doi.org/10.3969/j.issn.1000-4602.2012.14.012
2012-01-01
Abstract:The surface aeration A/A/O oxidation ditch process was used in Jingkou WWPT in Chongqing City,and the recent design capacity was 2×104 m3/d.The process flow,the influent and effluent quality,the design parameters of the main structures and the technological features were introduced.Aiming to improve the efficiency of nitrogen removal and reduce energy consumption,the productive control strategies were carried out in Jingkou WWTP.The operation results indicated that the process showed a stable operation,a high nitrogen and phosphorus removal efficiency and a strong shock load resistance.The effluent quality met the first level B class criteria specified in the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002).
What problem does this paper attempt to address?