Application of Mathematic Simulation Technology to Trouble-shooting and Operational Optimization of Wastewater Treatment Processes

Xiao-di HAO,Hong-wei SONG,Yuan-sheng HU,Er-cheng HAO,Jun ZHOU,Yi-ping GAN,Hong-chen WANG
DOI: https://doi.org/10.3321/j.issn:1000-4602.2007.14.026
2007-01-01
Abstract:The operation problems of reversed A2/O process in a large municipal wastewater treatment plant were diagnosed using TUD model and AQUASIM simulation software,and the optimization schemes were proposed and simulated.The results show that lack of carbon source,especially VFA,in the influent and shorter anaerobic HRT are key factors to limit nutrient removal.Towards overcoming these two problems,some optimization measures were proposed and simulated,such as reconfiguration of aeration tanks,addition of external carbon source,bypassing the primary settler,reconstruction of UCT system and combination with phosphorus recovery.It was predicted by simulation that good operation results may occur by taking each proposed optimization measure.