Simulation-based Diagnosis and Optimization of Suspended Carrier Biofilm Process

Hong-tao PANG,Yong QIU,Xiao-fei XUE,Hong-bo LIU,Yuan-yuan GUO,Xiu-guang JIANG
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2017.03.005
2017-01-01
Abstract:The operating problem of suspended carrier biofilm process in a municipal wastewater treatment plant was simulated and diagnosed using BioWin software.The influence of dissolved oxygen concentration,excess sludge discharge,reflux ratio and suspended carrier addition method was analyzed.An optimized operation scheme of the effluent quality for meeting the first level B criteria was proposed,and the full-scale verification tests were performed.The simulated results showed that the short sludge retention time was the restrictive factor of not meeting the standard for the effluent ammonia nitrogen concentration.The priority order of parameter adjustment was the sludge discharge,reflux ratio,suspended carrier addition method and dissolved oxygen.The fuR-scale verification results indicated that the effluent ammonia nitrogen concentration could meet the standard by increasing dissolved oxygen and extending sludge retention time.
What problem does this paper attempt to address?