Domination and Effect of Multi-parameters in Direct Chill Casting based on Establishment of Thermo Model by Numerical Simulation and Experiment
Jian Hou,Qichi Le,Liang Chen,Yonghui Jia,Chenglu Hu,Mohamed EI. Amine Ben Seghier
DOI: https://doi.org/10.1016/j.jmrt.2023.09.308
IF: 6.267
2023-10-07
Journal of Materials Research and Technology
Abstract:In this paper, a mathematical model validated by in-situ temperature measurement data of the direct chill (DC) casting process has been established in order to study the domination and effect of multi-parameters including secondary cooling water flow rate ( Q ), casting speed ( V ), condition of primary cooling, and spraying water temperature ( T w ) on DC casting index of sump depth ( d sump ), maximum and minimum temperature gradient ( T g,max and T g,min ) at mushy zone and shape of solidus line. Further, the height of impingement zone ( Hip ) is systematic quantitative analysis by a novel designed test ( Hip=1.08865Q`+0.06272V−4.75597 ). The calculated temperature using the numerical simulation exhibits a good match with the actual temperature measurement data. The results of multi-factors on index by the designed orthogonal test indicate that V dominates the d sump ( dsump=0.033+27.74V ) and T g,min ( Tg,min=2569.15−766342.20V ) at mushy zone, Q dominates the T g,max ( Tg,max=9195.12+2344770Q−27.83Tw ) by analysing the range ( R ), variance ( S ) and significance ( F ). Likewise, by discussing the combination of R , S , F and microstructure observation, the priority influencing the shape of solidus line at center part was V . The Q dominates the shape of solidus line at the position between the center and edge part.
materials science, multidisciplinary,metallurgy & metallurgical engineering