Abstract:During the Wenchuan earthquake,a 6-storey RC frame structure located in Dujiangyan City sustained serious damage at the first story,which served as park area and was essentially a soft story.However,the upper stories of this building were almost untouched.To retrofit the structure,the seismic isolation technology was applied at the tops of first story columns.The columns of the first story were restored and strengthened,and the lead rubber bearings were installed at the top of the first story columns.The weak story of the structure was changed to an isolation story,and the function of the first story was recovered.Thanks to the isolation effect,the upper story can also satisfy the seismic forces according to the new fortification requirements,which was upgraded after the Wenchuan earthquake.In this project,a structure analysis program called SAP2000 was used for the time-history analyses.The base structure below the seismic isolation layer was designed by using PKPM based on the time-history analysis results.