The research of the novel heavy metal chelating agent in the treatment of acid copper-containing wastewater

ZHANG You-xian,JIANG An,CUI Tao
DOI: https://doi.org/10.3969/j.issn.1004-874X.2011.17.045
2011-01-01
Abstract:Treatment of wastewater containing copper ions by the novel heavy metal chelating agent EX2000 have been studied.The effects of EX2000 dosage,stirring time and settling time on the efficiency of copper ion-removal have been investigated.The optimum conditions had been determined that EX2000 dosage was 15 mL,stirring time was 10 min at room temperature and settling time was 25 min.Under the optimum conditions,the removal efficiency of Cu2+ could reached to 99.41%,and the concentration of Cu2+ in treated wastewater was below 0.038 mg/L.It meet national emission standards(0.5 mg/L).
What problem does this paper attempt to address?