Study on treatment of wastewater containing complex copper by iron powder assisted Fenton

Jin Jierong,Chen Hansong,Yang Yueping,Ye Guoxiang,Shen Yanqun
2010-01-01
Abstract:Iron powder reduction assisted Fenton oxidization technic was used to treat industrial wastewater containing complex copper.The breaking complexing effect of complex copper in this combined process was investigated,the influence of H2O2 dosage,initial pH,reaction time,initial Cu(Ⅱ) concentration of wastewater,different diameter of iron powder on copper removal efficiency at normal temperatures were discussed,and the possible mechanism was also involved.The result showed that under the 50 mg/L Cu(Ⅱ) concentration when the conditions were controlled as follow: initial pH=3,iron powder was overused,H2O2 dosage was at H2O2∶COD=1.5∶1(mass ratio),reaction time was 30 minutes,and precipitation pH=9,COD and copper removal rates were 86.5% and 99.9%,respectively,which could meet the new discharge standard of GB21900-2800.And further studies showed that the iron sizes had little effect on treatment efficiency,so using the industrial iron powder could have a good performance.
What problem does this paper attempt to address?