Error Calibration of Fluxgate Magnetometers in Arbitrary Attitude Situation

PANG Hongfeng,LUO Shitu,CHEN Dixiang,PAN Mengchun,ZHANG Qi
DOI: https://doi.org/10.3969/j.issn.1671-7449.2011.04.020
2011-01-01
Abstract:Diversionary error of three-axis fluxgate magnetometer can not be avoided when its attitude changes.The main reasons are non-orthogonality between axes and different amplification of each axis.So,it is necessary to research calibration method and improve measurement precision.A stable magnetic circumstance is selected to calibrate a Germany DM-series three-axis fluxgate magnetometer.Firstly,the magnetometer attitude changes arbitrary.Secondly,the least squares method is used to estimate calibration parameters,and then,diversionary error is suppressed.Lastly,with the magnetometer attitude changing arbitrary at the validation place,the calibration parameters are used to reduce diversionary error.Experimental results show that the diversionary error at the calibration place and the validation place are suppressed from 106 nT and 89 nT to 27 nT and 23 nT,respectively.Diversionary errors are reduced greatly,which demonstrates that the calibration performance is effective.
What problem does this paper attempt to address?