Error calibration of three axis magnetometer based on Gauss-Newton iteration algorithm

Pang Hongfeng,Pan Mengchun,Wang Wei,Zhang Qi,Luo Shitu
DOI: https://doi.org/10.3969/j.issn.0254-3087.2013.07.010
2013-01-01
Abstract:In three axis magnetometers,scale factor,bias and non-orthogonality errors of the axes exist,so it is important to study its calibration method.The magnetometer calibration model is deduced based on scalar calibration method,and a magnetometer calibration method based on Gauss-Newton algorithm is proposed.A high precision proton magnetometer is used to provide the magnetic field intensity reference value.A nonmagnetic turntable is used to rotate the magnetometer,and during the rotation process the magnetometer records sample data continuously,which makes the measurement data more applicable and representative.Simulation results show that the magnetometer error is reduced from 162.135 nT to 1.467 nT.Experiment results show that,after calibration,the measurement errors of the magnetometer rotating three axes are reduced from 1133.887 nT,1317.554 nT,1303.994 nT to 36.964 nT,20.922 nT,15.664 nT,respectively,which shows that the proposed method can effectively reduce the measurement error of the magnetometer and obviously improve the precision of the three axis magnetometers.