Error calibration of three axis magnetometer based on UKF and equipment

Hongfeng Pang,Mengchun Pan,Chen Dixiang,Luo Shitu,Feilu Luo
2012-01-01
Abstract:The model parameter estimation method based on unscented Kalman filter(UKF) is proposed to calibrate the scalar and vector errors of three axis magnetometer.A high precision proton magnetometer is used to measure the true value of the magnetic field scalar;a nonmagnetic turntable is used to rotate the magnetometer omni-directionally and the calibration model parameters are estimated after rotation.Using this method,the parameters of a DM-050 magnetometer are estimated,and these estimated parameters are used to calibrate its scalar and vector errors.Simulation results show that the estimated parameters are consistent with the actual parameters.After calibration,the scalar error is reduced from 427.9 nT to 2.06 nT;the vector errors of X,Y,Z axes are reduced to 1.84 nT,1.96 nT and 1.72 nT,respectively.In addition,the method using UKF to estimate magnetometer model parameters is proved to have good repeatability;and the influence of noise on the UKF performance is discussed.Experiment results show that the magnetometer error is reduced from 114.94 nT to 14.47 nT,which indicates that the proposed method can improve the precision of three axis magnetometer.