Primary Beam-Loading Tests on DC–SC Photoinjector at Peking University

JK Hao,XY Lu,YT Ding,SW Quan,SL Huang,K Zhao,BC Zhang,LF Wang,L Lin,F Jiao,GM Wang,DT Xie,F Zhu,BP Xiao,R Xiang,J Chen
DOI: https://doi.org/10.1016/j.nima.2005.10.063
2006-01-01
Abstract:The DC–SC photoinjector is a compact electron gun integrating a DC pierce gun with a 1.3GHz 1+1/2 cell superconducting cavity. A test facility of the DC–SC photoinjector had been installed in Peking University and beam-loading tests at 4.4K have been finished. To date the gradient of 6MV/m has been achieved. The maximum energy gain is 1.1MeV at 4.4K. With average beam current of 270μA, the measured rms emittance is about 5mmmrad at the beam energy of 500keV. In this paper some of the experimental results are summarized.
What problem does this paper attempt to address?