Stable Operation of the Dc-Srf Photoinjector
Shengwen Quan,Jiankui Hao,Lin,Feng Zhu,Fang Wang,Liwen Feng,Senlin Huang,Zhiwen Wang,Xiaodong Wen,Peiliang Fan,Huamu Xie,Kexin Liu,Kui Zhao,Jiaer Chen
DOI: https://doi.org/10.1016/j.nima.2015.07.025
2015-01-01
Abstract:To obtain low-emittance electron beams with high average current, superconducting radio frequency photocathode guns have been developed by several laboratories worldwide. A DC-SRF injector, which combines a DC pierce gun and a superconducting cavity, has been developed at Peking University. Recently, stable operation of the DC-SRF photoinjector has produced encouraging results. The average beam current of 1mA in macropulses of 7ms with a repetition rate of 10Hz has been reached and can be kept at about 0.5mA for routine operation. In this paper, we describe the DC-SRF photoinjector and will discuss the experiments and the test results.