Performance of Bialkali Photocathode in DC-SRF Photoinjector

Dongming Ouyang,Yonglong Zhao,Huamu Xie,Xinkai Zhang,Sheng Zhao,Liwen Feng,Kexin Liu,Senlin Huang
DOI: https://doi.org/10.1016/j.nima.2021.166204
2022-01-01
Abstract:To obtain a low emittance, high current electron beam, a bialkali photocathode (K-Cs-Sb) was adopted in an upgraded DC-SRF photoinjector at Peking University. Based on the design and manufacture of the preparation and transport systems, a study of the K-Cs-Sb photocathode deposition and an electron beam performance test was carried out. The main improvement in the recipe is to reduce the cesiation process from ~50 min to ~6 min, and the lifetime of K-Cs-Sb photocathode can be increased, obviously, while the QE remains the same. During a performance test with a beam, a degradation in QE was found at 36 K, which is the lowest temperature for the operation of K-Cs-Sb photocathode in gun to date. However, the QE of K-Cs-Sb photocathode still exceeds 0.3% and can deliver an electron beam with a bunch charge of ~150 pC and a repetition rate of 1 MHz. This QE is higher than reported at cryogenic temperature for SRF electron guns.
What problem does this paper attempt to address?