Drive Laser System Of A High Average Current Photocathode Electron Gun In Pku

Xy Lu,L Lin,K Zhao,Sw Zhang
DOI: https://doi.org/10.3321/j.issn:0254-3052.2004.08.018
2004-01-01
Abstract:The precept of DC-SC photoinjector is to combine a DC photocathode electron gun and the superconducting cavity together. This scheme is specially adequate to provide the high average beam current. In this paper, authors have described the drive laser system for the DC-SC photoinjector of PKU version. This system is mainly composed of GE-100-XHP laser, a passive mode locked Nd: YVO4 laser, CLX-1100 timing controller from TBP, Switzerland, self-developed high efficiency SHG and FHG and laser beam transmission system. After experimental test, the laser power of 266nm is more than 1 W, the jitter between laser pulses and the RF reference signal is less than 1 ps. By use of this laser system, we have observed more than 500muA electron current from Cs2Te cathode.
What problem does this paper attempt to address?