Shielding analysis for ITER equatorial bio-shield plug

DANG Tong-qiang,YING Dong-chuan,YANG Qi,ZENG Qin,WANG Guo-zhong,ZOU Jun,LONG Peng-cheng,WU Yi-can
2011-01-01
Abstract:ITER equatorial port cell outside bio-shield plug is a place for allowing free personnel access after shutdown which accommodates various sensitive equipment and pipes.To ensure the personnel safety in port cell after shutdown,the distribution of dose rate in port cell was studied.Based on VisualBUS(CAD-Based Multi-Functional 4D Neutronics Simulation System),dose rate calculations were completed in port cell after shutdown.The result showed that dose rates in port cell are still 2 orders of magnitude more than desired limit(10 μSv/h)after one day shutdown.The optimization of bio-shield was needed.