Dosimetry study in Hybridintensity modulated radiotherapy after breast cancer surgery

MA Zhao,ZHANG Wei,WANG Xiaohui,MA Jinbo,ZANG Rukun,XIA Yujun
DOI: https://doi.org/10.3969/j.issn.1001-9510.2013.05.012
2013-01-01
Abstract:Objective To evaluate the dosimetric benefits of the hybridintensity modulated radiotherapy(Hy-IMRT) after breastconserving surgery.Methods For each of 10 chosen patients with breast cancer,three-dimensional conformal radiotherapy(3DCRT)and Hy-IMRT were designed.The prescribed dose for planning target volume(PTV) was 50 Gy/25f.Dosimetric comparisons of PTV dose distribution,homogeneity index(HI) and dose of organs at risk(OAR) between the two plans were performed on each patient by dose volume histogram(DVH).Results The D2% of Hy-IMRT was statistically lower than that of 3DCRT(t =-9.821,P<0.05),and the D98% was statistically higher than that of 3DCRT(t=3.879,P<0.05);The HI of Hy-IMRT was statistically lower than that of 3DCRT(t =-7.657,P<0.05);There was no signifeicant difference in the mean dose(Dmean) between the two plans.The lung(V20、V30) in Hy-IMRT paln was lower than 3DCRT plan(t=-3.401、-4.117,P<0.05).There was no statistical difference of exposure dose to other OARs between the two plans.Conclusion Hy-IMRT can improve target dose uniformity,HI and protect the organs at risk well compared to the 3DCRT in patients with breast cancer after the breast-conserving surgery.
What problem does this paper attempt to address?