Comparison and Analysis of Dosimetry in Three Kind of Plan of Whole Breast Radiation Therapy after Breast-Conservation Treatment in Breast Cancer

HAN Baoshan,ZHANG Li,QIAO Li,CHEN Ming
DOI: https://doi.org/10.3969/j.issn.1674-4721.2012.04.004
2012-01-01
Abstract:Objective To compare the dosimetric distribution between conventional radiotherapy(RT),three-dimensional cnformal radiotherapy(3DCRT),and intensity-modulated radiotherapy(IMRT) for left-sided whole breast treatment.Methods Ten patients with left-sided breast-conserving surgery and whole breast irradiation were selected.For each patient,the RT,3DCRT and IMRT with 5 fields were prepared using Eclipse 7.3 treatment planning system.Prescription dose was set to 50 Gy to planning target volume(PTV) in 25 fractions.PTV dose coverage and dose to normal tissues were evaluated.Results Compared with RT and 3DCRT plans,IMRT provided a significant improvement in PTV dose coverage,conformity and homogeneity.The V20 of ipsilateral lung was(29.4±4.6)%(RT),(26.7±4.6)%(3DCRT),and(22.6±1.8)%(IMRT),respectively.The V30 of ipsilateral lung was(26.4±5.2)% for RT(23.4±4.5)% for 3DCRT,and(16.2±1.6)% for IMRT.The V30 of heat was as follows:(21.9±6.0)% for RT,(14.6±3.5)% for 3DCRT,and(8.0±3.8)% for IMRT,difference had statistical significance.Conclusion Compare with RT and 3DCRT,IMRT plans can significantly improve the target the homogeneity and conformity and IMRT reduced the irradiated volume of OARs in high dose area but increased the irradiated volume of OARs in low dose area.
What problem does this paper attempt to address?