Dosimetric comparison of volumetric -modulated arc therapy and intensity -modulated radiation therapy for breast cancer

Jin Zhao,Wenan Wu,Juan Liao,Yan Ju,Jing Liang,Liping Song
DOI: https://doi.org/10.3969/j.issn.1672-4992.2016.09.027
2016-01-01
Abstract:Objective:To compare the dosimetric difference in VMAT and IMRT planning for breast cancer.Methods:Varian Eclipse,ten patients received radiotherapy alone after breast-conserving surgery were randomly selected.For each patient,two plans(VMAT and IMRT)were designed.In each plan,the volume of planning target volume (PTV)received prescription dose was not less than 95%.The dosimetric parameters were assessed with dosevolume histogram (DVH)and mean dose in PTV and organ at risk(OAR).Results:The irradition volume and meandose of heart and V5 of the lung can be increased by VMAT.Better conformal index(CI)and homogeneity index (HI)of PTV can be achieved.The MU and the therapy time can be reduced by the VMAT.Conclusion:The design ofVMAT plan for breast cancer should combined with clinic.VMAT can be considered for patients with good order incardio-pulmonary function.
What problem does this paper attempt to address?