Improved Assay for The Determination of Paclitaxel Injection by HPLC

Wu Zheng-hong,Fan Wen-yuan,Bao Yu-rong,Yu Na
DOI: https://doi.org/10.19778/j.chp.2006.05.021
2006-01-01
Abstract:Objective:To establish a new HPLC method for determination of Paclitaxel Injection.Method:The concentration of Paclitaxel Injection was assayed on a Shim-Pack CLC-ODS column(4.6×250mm,5μm)with a mobile phase consisting of acetic acid-water-methanol(0.1∶30∶70)at a flow rate of 1.0ml/min and detected at 227nm.The column temperature was 35℃.Results:The calibration curve was linear(r=0.9998)in the range of 8.8-35.2μg/mL for paclitaxel.The mean recovery was 101.3%.Conclusion:The improved method was a sensitive,reproducible and simple assay.It is suitable for the determination of Paclitaxel Injection.
What problem does this paper attempt to address?