A RP-HPLC method for determination of paclitaxel in its solid dispersion

Liu Xiang-Rui,Wu Ke-Chun,Zhang Chun-Hui,Zhang Xuan,Zhang Qiang
2007-01-01
Abstract:Aim To develop and validate a RP-HPLC method for the analysis of paclitaxel in a solid dispersion. Methods Paclitaxel and the internal standard norethisterone were separated using a Phenomenex ODS 3 column and monitored at a wavelength at 227 nm. The isocratic mobile phase consisting of methanol-acetonitrile-water (40:30:30, V/V) was pumped at a flow-rate of 1.0 mL·min-1. The dissolution studies were performed according to published studies. Results Under these chromatographic conditions, the calibration curve was linear in the range of 4-40 μg·mL-1 with the correlation coefficient of 0.9999. The mean recovery was 98.42 % (RSD = 1.19 %). At the 60 min time point, the dissolution of paclitaxel from the solid dispersion was nearly 100 %, however, the original form of paclitaxel was about 30 %. Conclusion The method was proven to be specific, accurate and precise for determining the dissolution of paclitaxel from solid dispersion.
What problem does this paper attempt to address?