Determination of Pacilitaxel in Microemulsion Injection by HPLC

Wu Kechun,Liu Xiangrui,Zhang Xuan,Zhang Qiang
DOI: https://doi.org/10.3969/j.issn.1002-7777.2006.10.015
2006-01-01
Abstract:A HPLC method was established for the determination of paclitaxel in the microemulsion injection.The separation was performed using a Phenomenex ODS3 column,and a mobile phase of methanol,acetonitril and water(40∶30∶30) with a flow rate of 1ml·min~(-1).The detective wavelength was at 227nm.Anorethisterone was used as internal standard.The calibration curve was in the range of 100~1000μg(r=0.9999).The average recovery was 99.77%(RSD=0.54%).The method is accurate and reliable.
What problem does this paper attempt to address?