STUDY ON DECHLORINATION OF fflGH-TEMPERATURE RECYCLE FLUE GAS FROM CCR REGENERATOR

Li Lin,Shen Benxian
DOI: https://doi.org/10.3969/j.issn.1002-106X.2006.12.004
2006-01-01
Abstract:The impact of temperature, gas velocity, HCl concentration, dechlorination agent particle diameter and operating pressure on the break-through was studied using high-temperature dechlorination agent and miniature reactor, and associated break-through curves are calculated. The test results show that the breakthrough is greater at the particle diameter of 2-4 mm. The proper operating conditions are; 500℃reactor temperature ,2-4 mm particle diameter, lower than 3 000 h -1 space velocity and 0.5 MPa pressure. Under these conditions, the recycle flue gas with 6 000μg/m3 HCl can be effectively treated.
What problem does this paper attempt to address?