Removal of NOx form Flue Gas by Integration NaClO2 Solution and Surplus Heat Recovery

Jingyi WANG,Qingyou GAO,Xi XU,Xiling ZHAO,Lin FU
DOI: https://doi.org/10.13198∕j.issn.1001-6929.2017.02.98
2017-01-01
Abstract:NOx from flue gas is a major source of air pollution. Challenges are posed because of the strict NOx emission standard implemented recently in China and the fact that tremendous heat is wasted in flue gas. We proposed a new method to integrate the removal of NOx with NaClO2 solution and recovery of the flue gas surplus heat in a counter-flow spray tower. The integrated experimental system and conducted experiments were set up to study the influence of various factors on de-NOx efficiency, including c(NaClO2), L∕G, spraying water temperature, etc. A higher de-NOx efficiency could be achieved with higher c ( NaClO2 ) ;lower pH and larger L∕G. When c( NaClO2 ) was 0. 0200 mol∕L and spraying water temperature varied from 30-80℃, there existed an optimal spraying water temperature, 64 ℃, resulting in a corresponding highest de-NOx efficiency of 36%. Meanwhile, L∕G and spraying water temperature had significant effects on the heat recovery efficiency. The results indicated that the heat recovery performance could be improved with higher L∕G and lower spraying water temperature. The experimental results showed that the de-NOx efficiency reached 40% and 26. 4 kW surplus heat was recovered, under the conditions that c ( NaClO2 ) was 0. 0150-0. 0200 mol∕L, liquid to gas ratio ( abbr. L∕G ) was 13. 8 m3∕L, gas temperature was 83 ℃ and the spraying water temperature was 48℃. The results indicated that the removal of NOx by integrating NaClO2 solution and surplus heat recovery of flue-gas is feasible.
What problem does this paper attempt to address?