Experimental Study of Air Transverse Distribution of Grate Stoker with Single-side Air Feed

JING Qiang-zheng,CHEN Zhi-liang,WANG Yu-feng,HUI Shi-en,ZHOU Qu-lan,XU Tong-mo
DOI: https://doi.org/10.3969/j.issn.1004-8774.2012.03.002
2012-01-01
Abstract:By improving the air transverse distribution of the grate stoker with single-side air feed,the operating efficiency of industrial boilers could be increased.The data of air distribution of four kinds of wind box models were obtained by pressure probe and tracer particles under different experiment conditions.The structure features of these wind box models are with empty chamber,with streamline air damper,with up-straight air damper,or with down-straight air damper,respectively.The effect of air damper near the air inlet on the flow distribution was analyzed.After several trials and improvements,an air damper structure was proposed which could solve the problem of flow balance and air transverse distribution.Comparing the flow resistance and distribution uniformity of the wind box models,it is found that the one with down-straight air damper is better than the others.The structure size of air dampers are provided,which could be used in design and retrofitting for energy saving.
What problem does this paper attempt to address?