Analysis of Conducted EMI Mechanism of AC / DC Converter

Chao SUN,Li-xin WANG,Gang ZHANG,Chao LIU
DOI: https://doi.org/10.13234/j.issn.2095-2805.2013.3.26
2013-01-01
Abstract:The AC/DC converter under two typical states was studied. Frequency domain waveform of the conducted EMI and the voltage waveform between the drain and the source of MOSFET were tested, and main parasitic parameters in the circuit were extracted. The reason for the formation of the several important peaks of the conducted EMI was found out through comparison and quantitative calculation. It can be concluded that the important factors that affect the conducted EMI of the switching power supply include the leakage inductance of the transformer’s primary side and secondary side, the parasitic capacitance between the source and the drain of the MOSFET and the parasitic capacitance between the MOSFET and the fins. The work state of the switching power supply changes when the switching device is turned on or off, and the residual energy in the leakage inductance or the parasitic capacitance of the device causes the high-frequency oscillation, and then inducing the peaks of the conducted EMI.
What problem does this paper attempt to address?