The Wall-Slip Testing System of Lubricating Grease in Flowing Pipe

Zhang Xiao-Guang,Zhang Xing-Gan,Sun Zheng
DOI: https://doi.org/10.3321/j.issn:0469-5097.2006.04.009
2006-01-01
Abstract:Due to the existence of wall-slip,rheologic models can be inconsistent with each other.So the corresponding experiments should be caried out for the rheologic model of certain tube-diameter,which is discommodious for engineering application.But in fact,by use of any rheologic instrument,the real rheologic models should be the same for one lubricating grease sample.Because of the primary normal stress difference,thixotropy and other factors,the rheologic models are be different.In order to eliminate all the influence factor except wall-slip,a precise testing system of wall-slip and a rational testing method were developed.The system was composed of the low pressure fluctuation pump,the precise pressure testing tie-in,the auto-collection instrument of testing data and so on.The lubricating grease flow in different-diameter pipes was tested,and the wall-slip was educed.The drag reduction function of wall-slip was validated and the real rheologic model without wall-slip don't change with the various tube diameters.
What problem does this paper attempt to address?