Effects of Geometry of Piezoelectric Actuator on Coupling Characteristics of Micro Nebulizer

Yang Mingwei,Zhou Zhaoying
DOI: https://doi.org/10.3969/j.issn.1671-4776.2009.04.007
2009-01-01
Abstract:To solve the energy coupling of multi-energy domains in the micro nebulizer,the piezoelectric-solid-liquid-sound coupling model of the micro nebulizer was built.The coupling characteristic was calculated numerically,the influence of the piezoelectric actuator geometry on the piezoelectric-solid-liquid-sound coupling was analyzed emphatically.The effect rule of the piezoelectric actuator geometry on the structural vibration and the pressure wave was achieved.The results show that the vibration of the nozzle film is also appearing with the piezoelectric actuator vibrating because of the coupling of the liquid layer and the solid,and there is the phase relation between them.The structural coupling,the resonant frequency,the phase differences of the back film and nozzle film are affected greatly by the geometry of the piezoelectric actuator,and there are the optimizal diameter ratio and thickness ratio between piezoelectric ceramic and back film.Therefore,only considering the amplitude of the piezoelectric vibration for the design of the micro nebulizer is not comprehensive,the nozzle film vibration and the phase relation between back film and the nozzle film must be considered simultaneously,and which can provide an important guidance for the optimal design of micro nebulizers.
What problem does this paper attempt to address?